  series am e15 - maz 15 w att | a c - dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8. i 1 of 4 north america only features: ? 4000vac i/o isolation ? rohs compliant ? operating temperature: - 40 to +80c ? soft start ? over load, over voltage, short circuit protection ? energy star compliant ? universal input: 90 - 26 4 vac, 47 - 440 hz ? ce, culus, cb approvals models single out put model input voltage (vac/hz) input voltage (vdc) output voltage (v) output current max (a) maximum c apacitive load ( f) efficiency (%) ame15 - 3.3smaz 90 - 264/47 - 440 120 - 370 3.3 3 4700 74 ame15 - 5smaz 90 - 264/47 - 440 120 - 370 5 3 2200 78 ame15 - 12smaz 90 - 264/47 - 440 120 - 370 12 1.25 1000 81 ame15 - 15smaz 90 - 264/47 - 440 120 - 370 15 1 680 81 ame15 - 24smaz 90 - 264/47 - 440 120 - 370 24 0.63 470 83 models dual output model input voltage (vac/hz) input voltage (vdc) output voltage (v) output current max (a) maximum capacitive load (f) efficiency (%) ame15 - 5dmaz 90 - 264/47 - 440 120 - 370 5 1.5 1000 78 ame15 - 12dmaz 90 - 264/47 - 440 120 - 370 12 0.63 470 80 ame15 - 15dmaz 90 - 264/47 - 440 120 - 370 15 0.5 330 81 i nput specifications parameters conditions typical maximum units current 115 vac 350 m a 230 vac 1 8 0 m a in rush current <2m s (cold start) 115 vac 1 0 a 230 vac 2 0 a leakage current 115 vac 0.1 ma 264 vac 0. 2 ma external fuse (recommend) slow blow type 2 a input dissipation no load <0.5 w under vol tage protection 88 vac output specifications parameters conditions typical maximum units voltage accuracy 2 % line regulation ll - hl 0.5 % load regulation (single) 0 - 100% 0.5 % cross regulation (dual) 25% load - 1 st out, 100% load ? 2 nd out 5 % transient recovery time 200 s transient response deviation 25% load step 2 % of vout ripple & noise * 20mhz bandwidth 100 mvp - p hold - up time min 20 ms * ripple & noise measured with 1f m/c and 47f e/c isolation specifications parameters conditions typical rated units tested i/o voltage 3sec 4000 v ac i solation resistance >1000 m cb
series am e15 - maz 15 w att | a c - dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8. i 2 of 4 north america only general specifications parameters conditions typical maximum units switching frequency 132 khz start up time 900 ms over load protection auto recov ery, hiccup mode >131 % over voltage protection zener diode clamp short circuit protection continous short circuit restart auto recovery operating temperature with derating over 55 o c - 40 to +80 o c storage temperature - 40 to +100 o c max case temp erature 100 o c temperature coefficient 0.02 % / o c cooling free air convection humidity 95 % rh weight 100 g dimensions (l x w x h) 2.56 x 1.83 x 0.79 inches 65.0 x 46. 5 x 20.1 mm , 0.5mm mtbf > 400 000 hrs (mil - hdbk - 217f, t=+25 o c ) case material plastic resin + fiberglass (flammability to ul 94v - 0) note: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. en vironment approval parameters conditions shock wave form: half sine wave acceleration amplitude: 5gn bump duration: 30 ms number of bumps: 18 (3 in each direction for every axis) converter operation before and after test, body mounted (on chassis) vibrations test mode: sweep sine 10 - 100hz, speed 0.05hz/s displacement: 1mm acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested converter operation before and after test, body mounted (on chassis) safety & emc specifications parameters agency approvals culus, ce , cb s tandards medical electrical equipment iec \ en \ ul 60601 - 1 , csa - c22.2 no. 601.1 - m90 information technology equipment en 60950 - 1:2006+a11:2009 emi - conducted and radiated emission en550 11 , class b harmonic c urrent emissions iec/en 61000 - 3 - 2, (en60555 - 2) voltage fluctuations and flicker iec/en 61000 - 3 - 3, (en60555 - 3) electrostatic discharge immunity iec 61000 - 4 - 2 rf, electromagnetic field immunity iec 61000 - 4 - 3 electrical fast transient/burst immunity i ec 61000 - 4 - 4 surge immunity iec 61000 - 4 - 5 rf, conducted disturbance immunity iec 61000 - 4 - 6 power frequency magnetic field immunity iec 61000 - 4 - 8 voltage dips, short interruptions immunity iec 61000 - 4 - 11
series am e15 - maz 15 w att | a c - dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8. i 3 of 4 north america only pin out specifications dimensions (top view) 2.56 (65.00) 2.13 (54.00) 0.69 (17.50) 0.18 (4.50) top view 1 2 3 4 5 6 0.39 (10.00) 0.23 (5.75) 0.26 (6.50) 1.83 (46.50) 0.52 (13.24) 0.23 (5.75) 0.69 (17.50) 0.52 (13.24) 0.39 (10.00) 0.79 (20.10) 0.2 (5.08) (min) ? 0.04 (1.00) dimensions: inch (mm) case tolerance: 0.1 (2.54) pin pitch tolerance: 0.012 (0.30) top view 1 2 3 4 5 6 div: 0.4 (11.6) 6 ?- 0.047 (? 1.2) pin single dua l 1 no pin no pin 2 ac input ( n ) ac input ( n ) 3 ac input ( l ) ac input ( l ) 4 - v output - v output 5 no pin common 6 +v output +v output
series am e15 - maz 15 w att | a c - dc / dc- dc converter www.aimtec.com tel: + 1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r8. i 4 of 4 north america only derating - 40 - 20 0 20 40 60 80 100 100 80 60 40 20 0 free air convection 55 o c safe operating area ambient temperature o c 85 note: 1. datasheets are updated as needed and as such, specifications are subject to change without notice. once printed or downloaded, datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the mo st current product specifications. 2. product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured a t an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of pu blishing this document. cas numbers and other limited information are considered proprietary and may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. warranty is in accordance with aimtec?s standard terms of sale available at www.aimtec.com.


▲Up To Search▲   

 
Price & Availability of AME15-MAZ12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X